black8898 wrote:Rob
I am trying to save Diagnostics but it does not seem to work , have got the diagnostic parameters on screen in edit mode and pc set to recieve I press output and nothing happens , am I doing something wrong ??
Alan
Hi Alan
Sorry, been tied up on other things.
The method of downloading the Diagnostics (Some of them anyway!!) numbers 0300 to 0499 is as described before.
With the PC set to receive and the Diagnostics on screen (Make sure you are on the screen that says "Diagnostics" at the top left of the list of numbers) you get to this by pressing the DGNOS/PARAM key usually twice and you should be on the correct screen.
Then with the "Edit" key pressed (And lit up!!) on the lower "Operators Panel" simply press the "Output" key on the upper keypad and if the PC has been correctly set to receive then the Diagnostics numbers 0300 to 0499 should be downloaded.
I have just tested this sequence (to make sure my memory is functioning!!) on one of my Cyclones and a Bridgeport Mill with Fanuc OM and both worked fine.
Regards
Rob
.