Customer writes in....

We have an old Microrouter Compact and need to replace the "old style" Emergency Stop Switch with the new style Emergency Stop Switch that has 4 prongs. Please tell us how to switch out from the old style to the new style. Thank you.
User avatar
Site Admin
Keep the wire pairs together (which are connected to the same block) - if there is more than one pair on the old estop (?)

Then wire them to 11-12 and 21-22 as pairs.
It does not matter which wire of the pairs goes to 11, just as long as the other wire of the matching pair goes to 12
Attachments:
NewEstopConnections.jpg
NewEstopConnections.jpg (103.5 KiB) Viewed 17029 times