WE HAVE THE FOLLOWING ERRORS ON A FANUC CYCLONE AND IT WILL NOT RUN

400 SERVO ALARM : (OVERLOAD)
414 SRVO ALARM :X AXIS DETECT ERROR
424 SERVO ALARM Z AXIS DETECT ERROR

NOT READY ALARM

DIAGNOS 720 11000100

ANY IDEAS ?
CNC Guru
CNC Guru
Posts: 1451
Joined: Tue 21 Feb , 2006 16:15 pm
Location: Denford UK
User avatar
CNC Guru
CNC Guru

Post by Steve »

Not sure on the cyclone what drive is fitted but.

720 bit 7 the LH bit means OVL An overload alarm has ocured. 720 bit 6 (the second in from the left) is IV A voltage shortage has occured. and finaly bit 2 the 3rd in from the right is An alarm of the regenerative discharge unit has occured.

I would check if the drive is a dual axis drive as both drives have the same fault. Check if there are any fuses on the drive.

Is the fault there at power up? Or do the axes try to move then trip out?

It is most probably a fault on the Drive board.
Site Admin
Posts: 3651
Joined: Fri 10 Feb , 2006 12:40 pm
Hardware/Software: Go to User Control Panel > Profile
Enter as much information about your CNC hardware and software as you can - it makes it easier for everyone to know what you're talking about then.
Location: Sunny Brighouse
Contact:
User avatar
Site Admin

Post by Denford Admin »

Just for reference:

Fanuc axis Diagnostic no 720-723 are axis error bits - one for each axis up to 4 (ie 720=X axis 721=Zaxis):
bit 0 (right hand side): overflow alarm (OFAL)
1: wire disconnection alarm (FBAL)
2: regen discharge unit alarm (DCAL)
3: overvoltage alarm (HVAL)
4: an improper current alarm (HCAL)
5: excessive current alarm (OVC)
6: voltage shortage alarm (LV)
7: overload alarm (OVL)
Site Admin
Posts: 3651
Joined: Fri 10 Feb , 2006 12:40 pm
Hardware/Software: Go to User Control Panel > Profile
Enter as much information about your CNC hardware and software as you can - it makes it easier for everyone to know what you're talking about then.
Location: Sunny Brighouse
Contact:
User avatar
Site Admin

Post by Denford Admin »

I would guess that a circuit breaker or fuse has blown, that supplies the axis drives.