last time when i switched on my denford triac fanuc atc milling the following alarm was appeared on the screen (system alarm 0466-25) please help me how it will be clear. any one help me regarding this.
thanks
tria fanuc atc system alarm 0466-25
Moderators: Martin, Steve, Mr Magoo
-
- Posts: 6
- Joined: Wed 30 Oct , 2013 11:01 am
tria fanuc atc system alarm 0466-25
- Attachments
-
- machine display image
- ge41.jpg (100.17 KiB) Viewed 6605 times
Re: tria fanuc atc system alarm 0466-25
It looks like you have lost all the machine parameters. Have you got a backup copy of them to reinstall?
Have you changed the backup batteries?
Have you changed the backup batteries?
-
- Posts: 6
- Joined: Wed 30 Oct , 2013 11:01 am
Re: tria fanuc atc system alarm 0466-25
thanks for reply sir, i have changed the battries a few months before. and i dont know how to get a backup copy to reinstall them. please advice me what i have to do know.Martin wrote:It looks like you have lost all the machine parameters. Have you got a backup copy of them to reinstall?
Have you changed the backup batteries?
thanks
jamil
Re: tria fanuc atc system alarm 0466-25
You need to power the control up with Reset & Delete both held in.
Then enter the 9000 parameters, then the full list followed buy the 450 diagnostics. Make sure you set Diagnostic 453.0 (Diagnostic setup marker)
Then enter the 9000 parameters, then the full list followed buy the 450 diagnostics. Make sure you set Diagnostic 453.0 (Diagnostic setup marker)
-
- Posts: 6
- Joined: Wed 30 Oct , 2013 11:01 am
Re: tria fanuc atc system alarm 0466-25
sir i have enter all parameters from service manual but 450 diagnostics list is not available in the given manual can u provide it or guide me where i can find this list.Martin wrote:You need to power the control up with Reset & Delete both held in.
Then enter the 9000 parameters, then the full list followed buy the 450 diagnostics. Make sure you set Diagnostic 453.0 (Diagnostic setup marker)
thanks
jamil
-
- Posts: 6
- Joined: Wed 30 Oct , 2013 11:01 am
Re: tria fanuc atc system alarm 0466-25
sir i need diagnostic and all other parameter list if u can provide meMartin wrote:You need to power the control up with Reset & Delete both held in.
Then enter the 9000 parameters, then the full list followed buy the 450 diagnostics. Make sure you set Diagnostic 453.0 (Diagnostic setup marker)