Hi guys.. looking for help again!!
Got an alarm showing 101 P/S..
Looking at our manual it offers the following:
The power was turned off while rewriting the contents of the memory in the part program storage and editing operation.
When this alarm is generated, set the setting data PWE to 1 and turn on the power while pushing the DELETE to clear the memory.
What is a PWE and how to i clear this alarm?
Thanks in advance
MArk
Denford TU150
Moderators: Martin, Steve, Mr Magoo
- Denford Admin
- Site Admin
- Posts: 3649
- Joined: Fri 10 Feb , 2006 12:40 pm
- Hardware/Software: Go to User Control Panel > Profile
Enter as much information about your CNC hardware and software as you can - it makes it easier for everyone to know what you're talking about then. - Location: Sunny Brighouse
- Contact:
Re: Denford TU150
There is a post here with some extra tips on Fanuc 101 PS ALARM:
viewtopic.php?f=9&t=527
The delete button held in on power up will clear your programs unfortunately, but there is no way around it.
PWE is a parameter at the top of the parameters/setting page somewhere - set it to 1 for "Parameter Write Enable" mode
You will probably need to turn the program protect keyswitch off (if you have one)
viewtopic.php?f=9&t=527
The delete button held in on power up will clear your programs unfortunately, but there is no way around it.
PWE is a parameter at the top of the parameters/setting page somewhere - set it to 1 for "Parameter Write Enable" mode
You will probably need to turn the program protect keyswitch off (if you have one)
Re: Denford TU150
Thanks for the info.. will give it a try and get back!
Thanks
Mark
Thanks
Mark
Re: Denford TU150
Yes.. spot on!
Cleared the fault and the memory.. which has got rid of some dead programs i needed to sort through, so good news all around!
Thanks again, your my hero!
Mark
Cleared the fault and the memory.. which has got rid of some dead programs i needed to sort through, so good news all around!
Thanks again, your my hero!
Mark