VR Milling 'NAN' shown in real machines axes display
or you get an error message:
xxx.xx is not a valid floating point value
Solution:
This has been seen in the field in France on PCs running French Windows 2000.
The problem is due to the decimal seperator in regional setting being set to a comma
To fix the problem, change setting...
Control Panel -> Regional Settings -> Number -> Decimal Symbol
From a comma ',' to a point '.'
This has been seen in the field in France on PCs running French Windows 2000.
The problem is due to the decimal seperator in regional setting being set to a comma
To fix the problem, change setting...
Control Panel -> Regional Settings -> Number -> Decimal Symbol
From a comma ',' to a point '.'
Last edited by bradders on Mon 20 Oct , 2008 13:18 pm, edited 1 time in total.
This has also caused problems with the material library in QuickCAM 2D.
See picture for regional settings screens from Control Panel.