CNC Guru
CNC Guru
Posts: 1251
Joined: Mon 13 Feb , 2006 12:35 pm
Location: Brighouse, England
Contact:
I get "Device Driver Call Failed" when running program in VR Milling Ver 5. The program runs and the spindle motor (Brand new motor) starts running and then i get the error message
CNC Guru
CNC Guru
Posts: 1251
Joined: Mon 13 Feb , 2006 12:35 pm
Location: Brighouse, England
Contact:
User avatar
CNC Guru
CNC Guru

Post by bradders »

ThIs error means that the VR Milling software is not talking to the machine tool

Check that the 7 segment display on the Baldor control board does not go off momentarily once the play button is pressed. If it does it could be the Over Voltage, Over Current or Over Temperature regulator on the Baldor control board is shutting down. if it does check out the thread below

viewtopic.php?t=1026&highlight=call
CNC Guru
CNC Guru
Posts: 1251
Joined: Mon 13 Feb , 2006 12:35 pm
Location: Brighouse, England
Contact:
User avatar
CNC Guru
CNC Guru

Post by bradders »

The 7 segment display on the Baldor control board does not go off momentarily once the play button is pressed.
CNC Guru
CNC Guru
Posts: 1251
Joined: Mon 13 Feb , 2006 12:35 pm
Location: Brighouse, England
Contact:
User avatar
CNC Guru
CNC Guru

Post by bradders »

Switch off the silver toggle switch on the spindle motor to isolate it from the system, it could be electrical noise from worn carbon brushes that is causing the communications error
CNC Guru
CNC Guru
Posts: 1251
Joined: Mon 13 Feb , 2006 12:35 pm
Location: Brighouse, England
Contact:
User avatar
CNC Guru
CNC Guru

Post by bradders »

I did this and the program runs OK, i.e. all the axes move with no error message
CNC Guru
CNC Guru
Posts: 1251
Joined: Mon 13 Feb , 2006 12:35 pm
Location: Brighouse, England
Contact:
User avatar
CNC Guru
CNC Guru

Post by bradders »

If a PCB with the E Stop relay etc is fitted then it could be a faulty suppressor
Site Admin
Posts: 3651
Joined: Fri 10 Feb , 2006 12:40 pm
Hardware/Software: Go to User Control Panel > Profile
Enter as much information about your CNC hardware and software as you can - it makes it easier for everyone to know what you're talking about then.
Location: Sunny Brighouse
Contact:
User avatar
Site Admin

Post by Denford Admin »

This is the PCB board Bradders is talking about:

Image

Certainly sounds like suppression has failed, or the motor is generating excessive noise due to a fault.
Site Admin
Posts: 3651
Joined: Fri 10 Feb , 2006 12:40 pm
Hardware/Software: Go to User Control Panel > Profile
Enter as much information about your CNC hardware and software as you can - it makes it easier for everyone to know what you're talking about then.
Location: Sunny Brighouse
Contact:
User avatar
Site Admin

Post by Denford Admin »

We have recently had a machine which was displaying "Device Driver Call Failed" numerous times whilst running a program.
It turned out to be a faulty USB cable - the one inside the electrical compartment from the back of the USB bulkhead fitting, to the Baldor control card. We are guessing the cable had a loose connection inside, as the problem could been made worse by moving the cable while the machine was running (not recommended practice!)