Search found 12 matches
- Tue 23 Oct , 2012 11:47 am
- Forum: EasiMill / EasiTurn
- Topic: easiturn 3 , data link problem. Please help!
- Replies: 13
- Views: 17595
Re: easiturn 3 , data link problem. Please help!
after the CR it must be some character.Any character works but i have choosen STX... If it just needs any character then how about LF (Line Feed) it may be that easyDNC has the option of appending CR+LF at the end or just CR If you have choosen the PNC2-4 mode then it transmit only CR at the end wh...
- Mon 22 Oct , 2012 16:34 pm
- Forum: EasiMill / EasiTurn
- Topic: easiturn 3 , data link problem. Please help!
- Replies: 13
- Views: 17595
Re: easiturn 3 , data link problem. Please help!
I'd contact easyDNC - I'm sure they will have a way of adding the STX to the end of each line. ps, I'd also see if ETX works from hyperterminal...that makes more sense than using an STX at the end. after the CR it must be some character.Any character works but i have choosen STX... i will contact t...
- Mon 22 Oct , 2012 15:35 pm
- Forum: EasiMill / EasiTurn
- Topic: easiturn 3 , data link problem. Please help!
- Replies: 13
- Views: 17595
Re: easiturn 3 , data link problem. Please help!
so ok ! i have found the problem and the problem is easyDNC . If i transmit with hyperterm for example the line G01X170Z470FX1500 in this format : ctrl+B (this is the STX (02) character) G01X170Z470FX1500L ctrl+M (CR(0D)) ctrl+B (STX(02)) the cnc returns me a ACK(06) and i can type the next block an...
- Mon 22 Oct , 2012 15:30 pm
- Forum: Electronics
- Topic: Data Link menu and the eternal RS232 hassle..
- Replies: 26
- Views: 37804
Re: Data Link menu and the eternal RS232 hassle..
so ok ! i have found the problem and the problem is easyDNC . If i transmit with hyperterm for example the line G01X170Z470FX1500 in this format : ctrl+B (this is the STX (02) character) G01X170Z470FX1500L ctrl+M (CR(0D)) ctrl+B (STX(02)) the cnc returns me a ACK(06) and i can type the next block an...
- Fri 19 Oct , 2012 21:28 pm
- Forum: EasiMill / EasiTurn
- Topic: easiturn 3 , data link problem. Please help!
- Replies: 13
- Views: 17595
Re: easiturn 3 , data link problem. Please help!
I have tried several thinks and then i have found a topic here in the forums and downloaded a serial monitor to see the ASCII traffic to find the problem. I think that the problem is that the cnc dont transmit a ACK charakter (06 in ASCII ) when it recieves the first bock. so the easyDNC waits for t...
- Fri 19 Oct , 2012 16:23 pm
- Forum: Electronics
- Topic: Data Link menu and the eternal RS232 hassle..
- Replies: 26
- Views: 37804
Re: Data Link menu and the eternal RS232 hassle..
i am having pretty much the same problem like you. I have to reports some bugs maybe for the easyDNC 4.7 but first i want to explain my setup. 1)I have made a cable 9 pin pc and 7 pin cnc like shown here https://www.denfordata.com/bb/viewtopic.php?f=34&t=3899 2)i have a easiturn 3 version 3.57 - 25/...
- Thu 18 Oct , 2012 18:38 pm
- Forum: EasiMill / EasiTurn
- Topic: easiturn 3 , data link problem. Please help!
- Replies: 13
- Views: 17595
Re: easiturn 3 , data link problem. Please help!
No one can help ? please i am student and i want to make it work :/ ? If the usual members don't reply then it's because they can't help...it's better to leave a post unanswered as less frequent members (who may know the answer) can view unanswered posts. If we reply with a "sorry, we don't know" t...
- Thu 18 Oct , 2012 18:36 pm
- Forum: EasiMill / EasiTurn
- Topic: easiturn 3 , data link problem. Please help!
- Replies: 13
- Views: 17595
Re: easiturn 3 , data link problem. Please help!
I think there could be a couple of reasons for this. Either a) the PC is sending all of the CNC program but the control only recognises the first block. b) The PC sends the first block and is waiting for the control to request the next block. I am not familiar with EasyDNC but here are some suggest...
- Wed 17 Oct , 2012 20:28 pm
- Forum: EasiMill / EasiTurn
- Topic: Easiturn 3 oil pump motor
- Replies: 0
- Views: 3503
Easiturn 3 oil pump motor
Hello i was wondering is someone have the motor from the oil pump . I think mine is not working :/
synchron 620 220v 60cy 3w 8rph
synchron 620 220v 60cy 3w 8rph
- Wed 17 Oct , 2012 11:06 am
- Forum: EasiMill / EasiTurn
- Topic: easiturn 3 , data link problem. Please help!
- Replies: 13
- Views: 17595
Re: easiturn 3 , data link problem. Please help!
ok i will ! Thank you but if someone can help please do this !Martin wrote:It may be worth sending Mr Magoo a pm.
- Wed 17 Oct , 2012 9:21 am
- Forum: EasiMill / EasiTurn
- Topic: easiturn 3 , data link problem. Please help!
- Replies: 13
- Views: 17595
Re: easiturn 3 , data link problem. Please help!
No one can help ? please i am student and i want to make it work :/
edit:
and another question. Why does my easiturn dont have G00 and G27 ?
edit:
and another question. Why does my easiturn dont have G00 and G27 ?
- Tue 16 Oct , 2012 14:23 pm
- Forum: EasiMill / EasiTurn
- Topic: easiturn 3 , data link problem. Please help!
- Replies: 13
- Views: 17595
easiturn 3 , data link problem. Please help!
Hello i have a easiturn 3 with PNC 3 and i have make a cable like shown in the attached picture. I use a 9 pin Male on pc side and a ethernet cable (ethernet has 8 cables in it and i use the 3 of them) lenght of the cable 1.5meter. I am using a windows xp pc. The communication between the cnc and th...