Search found 5 matches
- Wed 19 Mar , 2014 17:57 pm
- Forum: Cyclone
- Topic: delete button not working
- Replies: 1
- Views: 3448
delete button not working
Can anyone help my delete button has stopped working. This happened after I had attempted to load a program and the memory was full after a few lines. Tried to delete it with no success. It won't let me delete programs in the memory or delete information in programs but will allow me to 'alter' and ...
- Tue 20 Aug , 2013 17:05 pm
- Forum: Cyclone
- Topic: Z+ overtravel
- Replies: 2
- Views: 4078
Re: Z+ overtravel
Martin wrote:Try powering up the control while holding P & CAN at the same time.
viewtopic.php?f=47&t=2444&p=8832&hilit= ... ncel#p8832
It worked!!!
Thanks very much, a weight of my mind.
- Tue 20 Aug , 2013 13:22 pm
- Forum: Cyclone
- Topic: Z+ overtravel
- Replies: 2
- Views: 4078
Z+ overtravel
Switched on the Denford Cyclone this morning when I went to send the turret to the home position it caused the following alarm to be displayed
520 overtravel : +Z
It's never done this before. Can anyone help?
520 overtravel : +Z
It's never done this before. Can anyone help?
- Tue 26 Apr , 2011 16:05 pm
- Forum: Cyclone
- Topic: Z- overtravel change
- Replies: 2
- Views: 4033
Re: Z- overtravel change
It worked! Many (belated) thanks for your help.Martin wrote:You will need to set PWE (perameter write enable) to 1.
Make sure the program protect key switch is dissabled.
Then go to parameter 705 & input -210000 (210mm) & press enter.
Don't forget to change PWE back to 0 when finished.
- Fri 08 Apr , 2011 14:46 pm
- Forum: Cyclone
- Topic: Z- overtravel change
- Replies: 2
- Views: 4033
Z- overtravel change
We have a Denford Cyclone, which has a GE Fanuc Series O-T controller. Up until recently we had a pneumatic chuck fitted but have now changed over to a manually operated chuck. The trouble is that the manual chuck does not extend as far out as the pneumatic one so the Z- over travel alarm is invoked...