This indicates FPGA has booted successfully.
Indicates FPGA 'walking ones' test on FPGA scratchpad has failed. HALT.
Indicates pseudo random number test on all of RAM has failed. HALT.
Indicates CAN controller reset has failed. HALT.
Indicates 'walking ones test' on the CAN controller has failed. HALT.
Indicates that power up test did not find any valid Firmware in Flash device
Indicates that new firmware is being loaded into the NextStep control
Normal indication that card is powered up - the 2 is the cards NODE number (default)
Axes disabled, normally after downloading Mint (MEX file) for first time, before
starting Denford S/W
Flashing E whilst Flash memory is being erased and mint (MEX) file is being
downloaded
Axis is enabled
A general error has occured (Mint failure maybe)
A SPLINE move is being executed
A circular move is being executed
A Flying shear (used in lathe threading moves) is being executed
Axis is in homing sequence
Axis is performing a positional linear move
Emergency Stop has been pressed - None Denford S/W-this is a solid S symbol