Search found 7 matches

by Ojones
Wed 17 May , 2023 9:10 am
Forum: Cyclone
Topic: Harrison TU150P alarms
Replies: 2
Views: 4205

Re: Harrison TU150P alarms

I've made a bit of progress with this in that i have identified and replaced the I/O board and power supply. I've wiped all memory and parameters and re entered everything i have manually. Now i get the following error "1020 OPTIONS?" I used to get "TSHARRISON 800 GROUP" on start up, but now its jus...
by Ojones
Thu 15 Dec , 2022 14:23 pm
Forum: Cyclone
Topic: Harrison TU150P alarms
Replies: 2
Views: 4205

Harrison TU150P alarms

The machine was working fine until moved to a different position in the workshop. Now on startup we get the alarms shown in the following alarms 1007 TURRET O/HEAT 1017 SPDL. DRIVE O/H 1021 X MOTOR O/HEAT I've reloaded all the parameters and diagnostics, but dont even get the TS Harrison text on sta...
by Ojones
Tue 19 Oct , 2021 10:14 am
Forum: Cyclone
Topic: fanuc OT single block not working.
Replies: 2
Views: 5503

Re: fanuc OT single block not working.

I've used these parameters, along with the bespoke 900 ones supplied with the machine and the ones for diagnostics. There are also some 8000 numbered ones listed in the manual, would these have an effect, but I'm not sure how to view or enter them.
by Ojones
Mon 18 Oct , 2021 23:34 pm
Forum: Cyclone
Topic: fanuc OT single block not working.
Replies: 2
Views: 5503

fanuc OT single block not working.

After reloading parameters manually after memory battery failure i cant seem to get the buttons relating to single block, opt stop etc to activate. they seem to be doing something as you can see the bits changing on diagnos screen when pressed. But they fail to light up or activate when in auto mode...
by Ojones
Sat 28 Mar , 2020 11:00 am
Forum: Cyclone
Topic: TU150P startup problem
Replies: 4
Views: 7620

Re: TU150P startup problem

Ive tried homing and nothing works, ive also wound both axis away from the switches by hand. The auxiliary socket doesn’t look like its ever had anything plugged in but i could try putting some links in if that might work. If i wanted to perform a complete reset as mentioned before and input the par...
by Ojones
Tue 24 Mar , 2020 14:26 pm
Forum: Cyclone
Topic: TU150P startup problem
Replies: 4
Views: 7620

Re: TU150P startup problem

Yes it is a Fanuc OT-A, I've got a manual which has all the parameters (some are printed and others hand written) would the diagnostics be with these? How would i go about performing a full reset? Another question before i do this, if i cant start the spindle and test motor rotation, could the phase...
by Ojones
Sun 22 Mar , 2020 21:18 pm
Forum: Cyclone
Topic: TU150P startup problem
Replies: 4
Views: 7620

TU150P startup problem

I've recently purchased an ex college TU150P, i know the machine has been standing for many years, so had to replace the memory batteries and I’m assuming all the parameters are lost. On powering up i get alarm 100 P/S and NOT READY ALARM flashing. Before I start checking cables etc.. would anyone h...