Search found 3 matches

by Ojones
Sat 28 Mar , 2020 11:00 am
Forum: Cyclone
Topic: TU150P startup problem
Replies: 4
Views: 729

Re: TU150P startup problem

Ive tried homing and nothing works, ive also wound both axis away from the switches by hand. The auxiliary socket doesn’t look like its ever had anything plugged in but i could try putting some links in if that might work. If i wanted to perform a complete reset as mentioned before and input the par...
by Ojones
Tue 24 Mar , 2020 14:26 pm
Forum: Cyclone
Topic: TU150P startup problem
Replies: 4
Views: 729

Re: TU150P startup problem

Yes it is a Fanuc OT-A, I've got a manual which has all the parameters (some are printed and others hand written) would the diagnostics be with these? How would i go about performing a full reset? Another question before i do this, if i cant start the spindle and test motor rotation, could the phase...
by Ojones
Sun 22 Mar , 2020 21:18 pm
Forum: Cyclone
Topic: TU150P startup problem
Replies: 4
Views: 729

TU150P startup problem

I've recently purchased an ex college TU150P, i know the machine has been standing for many years, so had to replace the memory batteries and I’m assuming all the parameters are lost. On powering up i get alarm 100 P/S and NOT READY ALARM flashing. Before I start checking cables etc.. would anyone h...