Search found 24 matches

by pant
Sun 18 Nov , 2018 16:40 pm
Forum: Electronics
Topic: TRIAC PC _DOS ERROR COMMUNICATION
Replies: 30
Views: 28197

Re: TRIAC PC _DOS ERROR COMMUNICATION

dir nikos

put a hard disk with windows 95
my email is gpantemis@gmail.com for more informations

greg
by pant
Tue 08 Dec , 2015 16:25 pm
Forum: StarTurn
Topic: HELP WITH TOOL OFFSETS
Replies: 0
Views: 10180

HELP WITH TOOL OFFSETS

i have starturn 8 The problem it is that tool offset functioning as it would be supposed. When it changes the tool and should it goes to the particular place, it goes other. I have made those who write the handbook and the tools go to different point, and no there that I have declared the 0,0. It ca...
by pant
Fri 05 Oct , 2012 5:35 am
Forum: Machines
Topic: ERROR NUMBER < 5 >
Replies: 15
Views: 26905

Re: ERROR NUMBER < 5 >

yesterday i open the box .
it looks like that
viewtopic.php?f=47&t=3715&hilit=Pull+al ... d+caps+off
how i test the valve??? may be it stick .
< Pull the solenoid caps off > ????
by pant
Thu 04 Oct , 2012 10:09 am
Forum: Machines
Topic: ERROR NUMBER < 5 >
Replies: 15
Views: 26905

Re: ERROR NUMBER < 5 >

thanks for your interesting. do you have any foto of < the air pressure switch > and where is it on the machine ??? I want to know what looks like i saw the other switches x ( 2 switch ), y (2 switch ) ,z ( 2 switch 1 up and 1down white limit switch on the Z axis ) , door , toolchange ( 4 switches)
by pant
Thu 04 Oct , 2012 6:42 am
Forum: Machines
Topic: ERROR NUMBER < 5 >
Replies: 15
Views: 26905

Re: ERROR NUMBER < 5 >

Yesterday I made certain movements. I revealed the all terminals that I cleaned and checked optically. It did not appear existed some problem. Now as long as it concerns the pressure they is in the 100 psi. For the limit switch on the Z axis when I step Limit switch overide button and home the machi...
by pant
Tue 02 Oct , 2012 12:39 pm
Forum: Machines
Topic: ERROR NUMBER < 5 >
Replies: 15
Views: 26905

Re: ERROR NUMBER < 5 >

what do you mean ????
explain please
by pant
Tue 02 Oct , 2012 11:12 am
Forum: Machines
Topic: ERROR NUMBER < 5 >
Replies: 15
Views: 26905

Re: ERROR NUMBER < 5 >

The air is set to 100psi
by pant
Tue 02 Oct , 2012 7:19 am
Forum: Machines
Topic: ERROR NUMBER < 5 >
Replies: 15
Views: 26905

Re: ERROR NUMBER < 5 >

dir sir Went to the school and the process was the following I open the computer afterwards the instrument. Immediately in the instrument comes out clue on the 7-segment LED display 5 or S. In the computer, I run the program afterwards from destor I step home you present the screen machine datum. Wh...
by pant
Tue 25 Sep , 2012 10:33 am
Forum: Machines
Topic: ERROR NUMBER < 5 >
Replies: 15
Views: 26905

ERROR NUMBER < 5 >

i have the TRIAC PC DEC 1992 SEE FOTOS HERE http://www.denfordata.com/bb/viewtopic.php?f=54&t=3492 with very labour I accomplished him to begin the last time. Suddenly when I went to open the instruments it showed me error in the clue with number 5. Nothing did not function despite only pressing him...
by pant
Mon 14 Nov , 2011 21:51 pm
Forum: Electronics
Topic: TRIAC PC _DOS ERROR COMMUNICATION
Replies: 30
Views: 28197

Re: TRIAC PC _DOS ERROR COMMUNICATION

The programme that works fine for triac pc with dos was

Fanucmd.go

NARROWSIMBOX 0
SHOWTOOL 0
USE3D 0
FANUC_SDEVICE machine
UTILS_MENU_1 Dos Access
UTILS_GO_1 dos
TOOLORIENT 0
HIGHSPINDLE 4000


Fanucmd.opt

IBM.RS2 2
$3F8 4 COM1
$3F8 4 MACHINE
DENFORD1.KBD 1
18.2 $2F8 3
VGA.CRT 0
FANUCMD.APP
by pant
Fri 11 Nov , 2011 21:17 pm
Forum: Electronics
Topic: TRIAC PC _DOS ERROR COMMUNICATION
Replies: 30
Views: 28197

Re: TRIAC PC _DOS ERROR COMMUNICATION

Thank you
Because i'm abord i'll tell you on Monday
by pant
Thu 10 Nov , 2011 5:39 am
Forum: Electronics
Topic: TRIAC PC _DOS ERROR COMMUNICATION
Replies: 30
Views: 28197

Re: TRIAC PC _DOS ERROR COMMUNICATION

Finally it worked. I am very satisfied and happy I suspect that the problem they was the cards. I removed and put the all cards, afterwards all via yeast it worked Your contribution they was despite very auxiliary. I have read a lot in my forum for problem and I acquired a lot of interesting things ...
by pant
Mon 07 Nov , 2011 12:46 pm
Forum: Electronics
Topic: TRIAC PC _DOS ERROR COMMUNICATION
Replies: 30
Views: 28197

Re: TRIAC PC _DOS ERROR COMMUNICATION

dir martin I have done that you write to me but....---> fanucmd.opt NARROWSIMBOX 0 SHOWTOOL 0 USE3D 0 FANUC_SDEVICE machine UTILS_MENU_1 Dos Access UTILS_GO_1 dos TOOLORIENT 0 HIGHSPINDLE 4000 HIGHFEED 2500 HIGHFEEDZ 1500 MAXCONTOUR 90 SLAVE_CONTOURFEED 0.15 SLAVE_CONTOURANGLE 0.15 XIO 1 ATC 0 Fanuc...
by pant
Sat 05 Nov , 2011 10:53 am
Forum: Electronics
Topic: TRIAC PC _DOS ERROR COMMUNICATION
Replies: 30
Views: 28197

Re: TRIAC PC _DOS ERROR COMMUNICATION

Martin

These i put in fanucm.opt(.go) or in flstep.opt (.go) ???
the same .opt & .go text do i use with the desktop ????
IBM.RS2 2
$3F8 3 COM1
$2F8 3 MACHINE
DENFORD1.KBD 1
18.2 $3F8 4
VGA.CRT 0
FANUCMD.APP
by pant
Sat 05 Nov , 2011 7:11 am
Forum: Electronics
Topic: TRIAC PC _DOS ERROR COMMUNICATION
Replies: 30
Views: 28197

Re: TRIAC PC _DOS ERROR COMMUNICATION

First thanks for your advice. Finally i have made triac to communicate with pc i pullout the eurocard and put it back again , then i use FLSTEP with com1 only (QUERTY KEYBORD ) in fanucmtr software running <fanucmd.exe > . the flstep.go was http://www.denfordata.com/bb/viewtopic.php?f=9&t=2298&hilit...
by pant
Thu 03 Nov , 2011 17:56 pm
Forum: Electronics
Topic: TRIAC PC _DOS ERROR COMMUNICATION
Replies: 30
Views: 28197

Re: TRIAC PC _DOS ERROR COMMUNICATION

hello I have old pc 486 with ONLY dos 6.2 . I run only in dos the 2 coms works OK tested with modem and software in the AUTOEXEC.BAT i have input the command MODE COM1:9600,o,7,1 & MODE COM2:9600,o,7,1 so when pc opens they coms install . Please can someone answer in the 5 questions above?????
by pant
Thu 03 Nov , 2011 10:17 am
Forum: Electronics
Topic: TRIAC PC _DOS ERROR COMMUNICATION
Replies: 30
Views: 28197

Re: TRIAC PC _DOS ERROR COMMUNICATION

SORRY
OK THANKS
I desperately want same solution for the students
by pant
Thu 03 Nov , 2011 7:32 am
Forum: Electronics
Topic: TRIAC PC _DOS ERROR COMMUNICATION
Replies: 30
Views: 28197

Re: TRIAC PC _DOS ERROR COMMUNICATION

HI because i'm sick i dont go to school fisrt the COM1 & COM2 its OK . the baud rate in the pc for the 2 coms is 2400 ( not 9200) ,8,1,n before that it was good to tell me 1) have i change the baudrate in the pc ??? and if yes what ??? 2) what is the exac cable to put from pc to machine and pc to de...
by pant
Tue 01 Nov , 2011 5:37 am
Forum: Electronics
Topic: TRIAC PC _DOS ERROR COMMUNICATION
Replies: 30
Views: 28197

Re: TRIAC PC _DOS ERROR COMMUNICATION

Thanks a lot for asking Yes All the combination i tried but nothing As i write the Triac was connected with 10 PCs before . Is it possible their is a dip switch in the Euro card that can change???? What aboute the Machine battery ????? May be the battery of PC ??? . As I wrote the baud rate of COM1 ...
by pant
Mon 31 Oct , 2011 22:41 pm
Forum: Electronics
Topic: TRIAC PC _DOS ERROR COMMUNICATION
Replies: 30
Views: 28197

Re: TRIAC PC _DOS ERROR COMMUNICATION

i forggot that com 2 connect to desktop tutor with senarios A & B